Features & Benefits

Outdoor

  • A-Pam DC inverter
    Latest high efficiency DC Inverter technology.
  • -4°F (-20°C) Heating
    Low ambient heating at -4°F (-20°C)
  • Blue Fin
    Improves heat exchange and prevents corrosion.
  • Outdoor Low Noise
    Reduce outdoor noise by 7~10 dB(A)
  • Low Standby Power
    The unit will consume very low power when the unit under standby mode.
  • Long Distance Piping
    Change to Long Piping Length (165+) – see below

Wall Mount

  • Child Lock
    Prevents unit ended and unsupervised use
  • Turbo Mode
    Cools or heats the room quickly.
  • Auto-Changeover
    Automatically alternates from heating to cooling to maintain the set temperature
  • Dry Function
    Dehumidifies air passing through the unit
  • Warm Start
    Ensures fan will not blow cold air during heating mode startup
  • Quiet Mode (Indoor)
    Minimizes indoor noise while maintaining comfort levels
  • Sleep Mode
    Ensures a comfortable environment during sleeping while saving energy
  • Long Distance Air Supply
    Optimized fan motor and air duct design allows long distance airflow up to 60 feet+
  • 3-D Airflow
    Distributes air evenly, simulating the airflow of a natural breeze
  • Auto Louver (Up/Down)
    Indoor louver oscillates up and down automatically
  • Auto Restart
    Automatic return to the previous setting after power failure
  • Self-Cleaning Evaporator
    Removes dust from condensed water during operation.
  • Healthy Filter
    Multiple choices of filters available and ensures the best indoor air quality use.
  • Easy installation clip
    Helps install a much better view in the backside of the unit and saves time and effort during installation service
  • 2-Way Piping Drain (Indoor)
    Allows installer to drain the condensation from either the left or right side, making installation easier
  • Self-Diagnosis
    The LED display can also show the error code and provide an easier way to service the unit
  • Room Card
    Insert the room card and start the system
  • Blue Fin
    Improves heat exchange and prevents corrosion

Slim Duct

  • Auto-Changeover
    Automatically alternates from heating to cooling to maintain the set temperature.
  • Warm Start
    Ensures fan will not blow cold air during heating mode startup
  • Quiet Mode (Indoor)
    Cools or heats the room quickly.
  • Sleep Mode
    Cools or heats the room quickly.
  • Auto Restart
    Automatic return to the previous setting after power failure
  • Self-Diagnosis
    The LED display can also show the error code and provide an easier way to service the unit.
  • Built-in Condensate Pump
    Cools or heats the room quickly.
  • Room Card
    Insert the room card and start the system
  • Blue Fin
    Improves heat exchange and prevents corrosion.
  • Compact Design
    At 7/ 5/16" tall, offers the lowest clearance in the industry.
  • Optional Motorized Louver
    Optional Sleek looking return and air supply grille for slim duct type of indoor units.

High Static Duct

  • Warm Start
    Ensures fan will not blow cold air during heating mode startup
  • Quiet Mode (Indoor)
    Minimizes indoor noise while maintaining comfort levels
  • Sleep Mode
    Ensures a comfortable environment during sleeping while saving energy
  • Auto Restart
    Automatic return to the previous setting after power failure
  • Self-Diagnosis
    The LED display can also show the error code and provide an easier way to service the unit
  • Built-in Condensate pump
    Built in drain pump help pumps condensate water to a drain or outside the building
  • Room Card
    Insert the room card and start the system
  • Blue Fin
    Improves heat exchange and prevents corrosion.
  • Compact Design
    At 7/ 5/16" tall, offers the lowest clearance in the industry.
  • Optional Motorized Louver
    Optional Sleek looking return and air supply grille for slim duct type of indoor units.

Compact Cassette

  • Turbo Mode
    Cools or heats the room quickly
  • Auto-Changeover
    Automatically alternates from heating to cooling to maintain the set temperature.
  • Dry Function
    Cools or heats the room quickly.
  • Warm Start
    Ensures fan will not blow cold air during heating mode startup
  • Quiet Mode (Indoor)
    Cools or heats the room quickly.
  • Sleep Mode
    Cools or heats the room quickly.
  • 1F(0.5C) Precise Temperature Control
    Accurate indoor temperature display allows +/- 1°F or 0.5°C
  • Auto Restart
    Automatic return to the previous setting after power failure
  • Self-Cleaning Evaporator
    Dust on evaporator will be removed by flowing water.
  • Self-Diagnosis
    The LED display can also show the error code and provide an easier way to service the unit.
  • Built-in Condensate Pump
    Cools or heats the room quickly.
  • Fresh Air Knockout
    Cools or heats the room quickly.
  • Room Card
    Insert the room card and start the system
  • Blue Fin
    Improves heat exchange and prevents corrosion.

Large Cassette

  • Turbo Mode
    Cools or heats the room quickly
  • Auto-Changeover
    Automatically alternates from heating to cooling to maintain the set temperature.
  • Dry Function
    Cools or heats the room quickly.
  • Warm Start
    Ensures fan will not blow cold air during heating mode startup
  • Quiet Mode (Indoor)
    Cools or heats the room quickly.
  • Sleep Mode
    Cools or heats the room quickly.
  • Auto Louver (4-Way)
    Cools or heats the room quickly.
  • Intelligent Sensor
    By automatically scanning the space and measuring both its size and the location of people, the intelligent eye help the unit to deliver the exact amount of hot or cold air needed to meet the desired temperature in the particular space
  • Auto Restart
    Cools or heats the room quickly.
  • Self-Diagnosis
    Cools or heats the room quickly.
  • Built-in Condensate Pump
    Cools or heats the room quickly.
  • Fresh Air Knockout
    Cools or heats the room quickly.
  • Room Card
    Insert the room card and start the system
  • Blue Fin
    Improves heat exchange and prevents corrosion.

Indoor Unit Specifications

Indoor Model NumberRated Cooling Capacity Btu/hrRated Heating Capacity Btu/hrLine Size (in)Drain PumpMax. Drain Lift Height (in)Max Static in.W.G (Pa)Dimension HxWxD (in)
MVAW007MV2AA700086001/4", 1/2"No//11x33.7x7.9
MVAW009MV2AA9000106001/4", 1/2"No//11x33.7x7.9
MVAW012MV2AA12000136001/4", 1/2"No//11x33.7x7.9
MVAW018MV2AA18000200001/4", 1/2"No//13.2x43.9x9.6
MVAW024MV2AA24000270003/8", 5/8"No//13.2x43.9x9.6
MVAW030MV2AA30000340003/8", 5/8"No//14.4x51.8x10.6
MVAB009MV2AA9000100001/4", 1/2"Yes27 1/2/10 1/4 X 22 7/16 X 22 7/16
MVAB012MV2AA12000135001/4", 1/2"Yes27 1/2/10 1/4 X 22 7/16 X 22 7/16
MVAB018MV2AA18000210001/4", 1/2"Yes27 1/2/10 1/4 X 22 7/16 X 22 7/16
MVAL009MV2AA9000100001/4", 1/2"Yes27 1/2/7 3/16 X 33 1/16 X 33 1/16
MVAL012MV2AA12000135001/4", 1/2"Yes27 1/2/7 3/16 X 33 1/16 X 33 1/16
MVAL018MV2AA18000210001/4", 1/2"Yes27 1/2/7 3/16 X 33 1/16 X 33 1/16
MVAL024MV2AA24000270001/4", 5/8"Yes27 1/2/7 3/16 X 33 1/16 X 33 1/16
MVAL030MV2AA30000340001/4",5/8"Yes27 1/2/7 3/16 X 33 1/16 X 33 1/16
MVAL036MV2AA36000400001/4",5/8"Yes27 1/2/7 3/16 X 33 1/16 X 33 1/16
MVAL042MV2AA42000470001/4",5/8"Yes27 1/2/7 3/16 X 33 1/16 X 33 1/16
MVAL048MV2AA48000540001/4",5/8"Yes27 1/2/7 3/16 X 33 1/16 X 33 1/16
MVAD007MV2AA700085001/4",1/2"Yes27 9/160.12 (30)7 5/16 X 33 7/16 X 16 9/16
MVAD009MV2AA9000105001/4",1/2"Yes27 9/160.12 (30)7 5/16 X 33 7/16 X 16 9/16
MVAD012MV2AA12000135001/4",1/2"Yes27 9/160.12 (30)7 5/16 X 33 7/16 X 16 9/16
MVAD018MV2AA18000200001/4",1/2"Yes27 9/160.12 (30)7 5/16 X 46 1/16 X 16 9/16
MVAD024MV2AA24000270003/8", 5/8"Yes27 9/160.12 (30)7 5/16 X 46 1/16 X 16 9/16
MVAH009MV2AA9500120001/4", 1/2"Yes23 5/80.80 (200)11 X 37 3/8 X 25
MVAH012MV2AA10500135001/4", 1/2"Yes23 5/80.80 (200)11 X 37 3/8 X 25
MVAH018MV2AA18000200001/4", 1/2"Yes23 5/80.80 (200)11 X 29 1/2 X 25
MVAH024MV2AA24000270003/8", 5/8"Yes23 5/80.80 (200)11 X 37 3/8 X 25
MVAH030MV2AA30000340003/8", 5/8"Yes23 5/80.80 (200)11 X37 3/8 X 25
MVAH036MV2AA36000400003/8", 5/8"Yes23 5/80.80 (200)11 X 53 7/8 X 29 1/8
MVAH042MV2AA42000470003/8", 5/8"Yes23 5/80.80 (200)11 X 53 7/8 X 29 1/8
MVAH048MV2AA48000540003/8", 5/8"Yes23 5/80.80 (200)11 X 53 7/8 X 29 1/8

Outdoor Unit Specifications

OutdoorModel NumberMVHP036MV2AAMVHP048MV2AAMVHP056MV2AA
Cooling Non-ductedRated Capacity Btu/hr36,00048,00056,000
Cooling DuctedRated Capacity Btu/hr36,00048,00056,000
Capacity Range Btu/hr7,000-36,0007,000-48,0007,000-56,000
Rated Power Input W3,3304,8005,580
SEER16.016.016.0
EER10.910.010.0
Heating Non-ductedRated Heating Capacity 47°F Btu/hr40,00054,00060,000
Heating Capacity Range Btu/hr8,000-40,0008,000-59,0008,000-63,000
Rated Power Input W3,4805,2506,150
HSPF10.010.010.0
Rated Heating Capacity 17°F Btu/hr24,00032,40036,400
Max. Heating Capacity 17°F Btu/hr25,60035,00038,000
Max. Heating Capacity 5°F Btu/hr22,40030,40033,000
Max. Heating Capacity-4°F Btu/hr21,88029,54032,280
Heating DuctedRated Heating Capacity 47°F Btu/hr39,50054,00060,000
Heating Capacity Range Btu/hr8,000-40,0008,000-58,0008,000-62,000
Rated Power Input W3,4805,2506,150
HSPF10.010.010.0
Rated Heating Capacity 17°F Btu/hr23,80032,40036,400
Max. Heating Capacity 17°F Btu/hr25,00035,00038,000
Max. Heating Capacity 5°F Btu/hr22,40030,40033,000
Max. Heating Capacity -4°F Btu/hr21,88029,54032,280
Operating RangeCooling °F(°C)23-115(-5~46)23-115(-5~46)23-115(-5~46)
Heating °F(°C)-4~75(-20~24)-4~75(-20~24)-4~75(-20~24)
Power SupplyVoltage, Cycle, Phase V/Hz/-208-230/60/1208-230/60/1208-230/60/1
Outdoor UnitCompressor TypeDC Interver Driven Rotary
Maximum Fuse Size A304040
Minimum Circuit Amp A25.437.838.8
Outdoor Noise Level dB545555
Dimension: HxWxD in (mm)52 3/4(1340) x 37 3/8(950) x14 5/8(370)
Weight (Ship/Net)-lbs (kg)265/247(120/112)271/254(123/115)271/254(123/115)
Indoor UnitMax Indoor units689
Refrigerant LineConnectionsFlare
Liquid / Suction O.D. in3/8", 5/8"
Factory Charge Oz123.0141.0141.0
Maximum Line Length Ft / m*984/300984/300984/300
Maximum Height Ft / m*164/50164/50164/50
Maximum Line Length for each individual indoor unit Ft / m*492/150492/150492/150

MRV-S Series

MRV-S bridges the gap between the 2~4 zone multi-split residential applications and three phase VRF light commercial needs. Haier’s MRV-S can have up to 9 indoor units. With a 984 ft. refrigerant line length, multi-storey applications and large building application are now possible.

Outdoor ModelMVHP036MV2AA, MVHP048MV2AA, MVHP056MV2AA
Compact CassetteMVAB009MV2AA, MVAB012MV2AA, MVAB018MV2AA
Large Cassette Indoor ModelsMVAL009MV2AA, MVAL012MV2AA, MVAL018MV2AA, MVAL024MV2AA, MVAL030MV2AA, MVAL036MV2AA, MVAL042MV2AA, MVAL048MV2AA
High Wall Indoor ModelsMVAW007MV2AA, MVAW009MV2AA, MVAW012MV2AA, MVAW018MV2AA, MVAW024MV2AA, MVAW030MV2AA
Slim Duct Type Indoor ModelMVAD007MV2AA, MVAD009MV2AA, MVAD012MV2AA, MVAD018MV2AA, MVAD024MV2AA
Selection Software
70.4 MB
Submittal Book
11.7 MB
Warranty Book
45.1 KB

Outdoor

Installation Manual
Service Manual

Wall Mounted Indoor

Installation Manual
Service Manual

Compact Cassette Indoor

Installation Manual
Service Manual

Large Cassette Indoor

Installation Manual
Service Manual

Slim Duct Indoor

Installation Manual
Service Manual

High Static Duct Indoor

Installation Manual
Service Manual